ÖLFLEX® EB CY 4X0,75
Control cable; 4X0.75; U0/U: 300 / 500 V; PVC; Core identification: Numbers; Shielded; Flexible

Please click on “Request for Quote” for price information and stock availability
In stock
SKU
0012642
In stock and estimated delivery in 5 working days
For Back Ordering of Out of Stock items in India & Globally, Tentative Lead Time is 4 - 6 Weeks. The actual delivery date will be confirmed within 3 to 5 days after placing an order
ÖLFLEX® EB CY 4X0,75 Control cable -  Primary Image
ÖLFLEX® EB CY 4X0,75 Control cable -  Primary Image ÖLFLEX® EB CY 4X0,75 Control cable -   Secondary Image
uv-resistant.
uv-resistant.
chemical resistance
chemical resistance
flame-retardant
flame-retardant
icon sturgeon signal
icon sturgeon signal
UKCA marked
UKCA marked
CE marked
CE marked

Benefits

  • Space-saving due to small outer diameters.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
  • Ideal protection against electromagnetic interference thanks to double screening made of aluminium-laminated foil and copper braided screening with a high degree of coverage.

Applications

  • For use in devices, machines and systems of the "intrinsic safety" ignition protection type ("i").
  • For intrinsically safe circuits according to IEC 60079-14 / EN 60079-14 / VDE 0165 (part 1).
  • For fixed installation and occasional flexing without tensile strain.
  • Can be used in dry, damp or wet environments.
  • Suitable for medium mechanical stress.
  • The PVC outer sheath is resistant to acids and alkalis and has limited oil resistance.
  • Suitable for outdoor use, subject to the temperature range.
Show less
Show all

Technical Attributes

General Information

Brand

ÖLFLEX®

Product type

Control cable

Weight

95 kg/km

Copper index

61.000 kg/km

Copper index (lb)

409.900 lb/10,000 ft

Electrical Characteristics

Nominal voltage

U0/U: 300 / 500 V AC rms according to IEC

test voltage conductor/conductor

3 kV

Test voltage core/screening

2 kV

Product Design

Cable dimension

4X0.75

Conductor cross-section (mm2)

0.75 mm²

Conductor material

Bare Copper

Conductor design

IEC 60228 class 5: fine-wire

Including protective conductor

No

Number of cores

4

Stranding type

Layered Stranding

Wrapping over stranding

Plastic film

Shielded

Yes

Type of overall screen

Tin-plated copper braiding

With armouring

No

Nominal outer diameter

7 mm

Shape of cable

Round

Core insulation base material

Polyvinylchloride

Core insulation base material, shortname

PVC

Base material outer sheath

Polyvinylchloride

Base material outer sheath, shortname

PVC

Cable insulation colour

blue

Core identification

Numbers

Core colour code

VDE 0293-1
EN 50334

Product Characteristics

Application area

Flexible
Fixed Installation

For continuous flexing

No

For torsional load

No

For intrinsically safe circuits according to

IEC 60079-14

Minimum bending radius, fixed installation

6 x outer diameter

Minimum bending radius in mm, fixed installation

42.0 mm

Minimum bending radius, occasionally moved

20 x outer diameter

Minimum bending radius in mm, occasionally flexing

140.0 mm

Temperature, fixed installation

-40 °C to 80 °C

Temperature, occasionally moved

-5 °C to 70 °C

Flame-retardant

Yes

Flame retardance according to

IEC 60332-1-2

UV-resistant

Yes

UV-resistant according to

DIN EN ISO 4892-2 method A

Chemical resistant

Yes

Halogenfree

No

Oil-resistant

No

PWIS-free

No

Certifications and Standards

CE marked

Yes

UKCA marked

Yes

EAC certified

Yes

EAC certification number

ЕАЭС N RU Д-DE.АЮ64.В.00130/20

VDE certified

No

DNV-certified

No

CPR fire class

Eca

Flame retardance tested according to UN/ECE-R118

No

Ecolab certified

No

Show less
Show all

Documentation

  • Notes

    • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
    • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.

Product Family List

All articles from ÖLFLEX® EB CY

Article number Number of cores Including protective conductor Conductor cross-section (mm2) Nominal outer diameter Copper index Weight
0012640 2 No 0.75 mm² 6.2 mm 43.000 kg/km 56 kg/km
0012641 3 No 0.75 mm² 6.5 mm 52.000 kg/km 70 kg/km
0012642 4 No 0.75 mm² 7 mm 61.000 kg/km 95 kg/km
0012643 5 No 0.75 mm² 7.7 mm 72.000 kg/km 108 kg/km
0012644 7 No 0.75 mm² 8.3 mm 89.000 kg/km 168 kg/km
0012645 12 No 0.75 mm² 10.9 mm 138.000 kg/km 208 kg/km
0012646 18 No 0.75 mm² 12.7 mm 211.000 kg/km 315 kg/km
0012647 25 No 0.75 mm² 14.8 mm 280.000 kg/km 435 kg/km
0012650 2 No 1 mm² 6.5 mm 51.000 kg/km 84 kg/km
0012651 3 No 1 mm² 6.8 mm 62.000 kg/km 79 kg/km
0012652 5 No 1 mm² 8.1 mm 88.000 kg/km 156 kg/km
0012653 7 No 1 mm² 8.8 mm 112.000 kg/km 192 kg/km
0012654 12 No 1 mm² 11.5 mm 185.000 kg/km 285 kg/km
0012655 18 No 1 mm² 13.9 mm 268.000 kg/km 395 kg/km
0012656 25 No 1 mm² 15.9 mm 354.000 kg/km 656 kg/km
0012660 2 No 1.5 mm² 7.1 mm 65.000 kg/km 87 kg/km
0012661 3 No 1.5 mm² 7.5 mm 82.000 kg/km 112 kg/km
0012662 5 No 1.5 mm² 8.9 mm 119.000 kg/km 148 kg/km
0012663 7 No 1.5 mm² 9.9 mm 154.000 kg/km 193 kg/km
0012664 12 No 1.5 mm² 13 mm 268.000 kg/km 324 kg/km
0012666 25 No 1.5 mm² 17.9 mm 530.000 kg/km 734 kg/km
Show less
Show all