KE91L Fe/CuNi JX 2x0,5 IEC
Extension cable; JX; IEC; PVC-PVC - Round; 2X0.5

Please click on “Request for Quote” for price information and stock availability
In stock
SKU
0161030
In stock and estimated delivery in 3 weeks
For Back Ordering of Out of Stock items in India & Globally, Tentative Lead Time is 4 - 6 Weeks. The actual delivery date will be confirmed within 3 to 5 days after placing an order
KE91L Fe/CuNi JX 2x0,5 IEC Extension cable -  Primary Image
KE91L Fe/CuNi JX 2x0,5 IEC Extension cable -  Primary Image
※The product image is a representative product and may differ from the actual product.
uv-resistant.
uv-resistant.
flame-retardant
flame-retardant
CE marked
CE marked

Benefits

  • Clear identification of the cable type based on the article name. Thermocouple cables: Abbreviation of the thermocouple ("K", "N", ...). Thermoelectric cables: Abbreviation of the thermocouple supplemented by an X ("JX", "LX", ...). Compensating cables: Abbreviation of the thermocouple supplemented by a C and, if applicable, an abbreviation for different compensating materials ("KCA", "RCB/SCB", ...).
  • Thermocouple cables can be used both directly as a thermocouple in a thermocouple element and as a reliable connection between the connection point and the reference junction.
  • Thermoelectric and power cables provide a reliable connection between the connection point and the cold junction.
  • Thermocouple and thermoelectric cables are made of the same alloy as the thermocouple. They correspond to accuracy class 1 or 2 according to IEC 60584, whereby class 1 offers the higher accuracy.
  • Thermocouple cables are designed for use up to the maximum temperature of the thermocouple, while thermoelectric cables are calibrated in the standardised application range.
  • Compensating cables use materials that have similar thermoelectric properties to the thermocouple element but are less expensive. They are calibrated in the standardised application range and correspond to accuracy class 2 in accordance with IEC 60584.
  • Numerous dimensions and alloys available for a wide range of applications.
  • Available in variants for applications with temperatures up to +1200 °C as well as for applications with increased radiation exposure, such as medical applications.

Applications

  • For transmitting the thermoelectric voltage of thermocouple elements in temperature measurement technology.
  • For temperature measurement in places where non-contact temperature measurement is not possible or practical.
  • For use with the SILVYN® HIPROJACKET and SILVYN® SSUE protective conduits.
  • For use with the FLEXIMARK® stainless steel FCC marking system.
  • For fixed installation and occasional flexing.
Show less
Show all

Technical Attributes

General Information

Product type

Extension cable

Weight

45 kg/km

copper index (lb)

195.000 lb/10,000 ft

Product Design

Thermoelectric and compensating cable type

JX

Cable dimension

2X0.5

Conductor cross-section (mm2)

0.5 mm²

Conductor design

16 x 0.20 mm

Including protective conductor

No

Number of cores

2

Shielded

No

Type of overall screen

Aluminium-laminated plastic foil

With armouring

No

Armouring type

Galvanised steel wire braiding

Min. outer diameter

3.3 mm

Nominal outer diameter

5.4 mm

Max. outer diameter

6.0 mm

Shape of cable

Round

Extension and compensating cables design

PVC-PVC - Round

Core insulation base material

Polyvinylchloride

Core insulation base material, shortname

PVC

Basic material of inner sheath

Silicone

Basic material of inner sheath, short form

SIR

colour inner sheath

black

Base material of outer sheath

Polyvinylchloride

Base material of outer sheath, shortname

PVC

Cable insulation colour

black

Cable insulation RAL colour

RAL 9005

Core identification

Colours

Core colour code

IEC 60584-3

Thermoelectric and compensating cable colour code

IEC

Product Characteristics

Application area

Flexible
Fixed Installation

Minimum bending radius, fixed installation

12 x outer diameter

Minimum bending radius in mm, stationary

64.8 mm

Minimum bending radius, occasionally moved

12 x outer diameter

Minimum bending radius in mm, occasionally flexing

64.8 mm

temperature, fixed installation

-40 °C to 80 °C

Temperature, occasionally moved

-5 °C to 80 °C

Flame-retardant

Yes

Flame retardance according to

IEC 60332-1-2

UV-resistant

Yes

UV-resistant according to

EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use)

Chemical resistant

No

Halogenfree

No

Oil-resistant

No

PWIS-free

Yes

PWIS-free according to

VDMA 24364-B2-L

Certifications and Standards

CE marked

Yes

UKCA marked

No

EAC certified

Yes

EAC certification number

ЕАЭС N RU Д-DE.АЮ64.В.00130/20

Flame retardance tested according to UN/ECE-R118

No

Show less
Show all

Product Family List

All articles from Extension- and compensating cables, paired

Article number Thermoelectric and compensating cable type Thermoelectric and compensating cable colour code Extension and compensating cables design Cable dimension Weight
0151001 LX DIN PVC-Round 2X1.5 40 kg/km
0151003 LX DIN SIR-Round 2X1.5 40 kg/km
0151005 LX DIN GL-GL - Oval 2X1.5 50 kg/km
0151006 LX DIN GL-GL-S-Oval 2X1.5 80 kg/km
0151007 LX DIN SIR-SIR-S-Oval 2X1.5 90 kg/km
0151010 LX DIN PVC-PVC - Round 2X1.5 79 kg/km
0151011 LX DIN PVC-PVC-S-Round 2X1.5 140 kg/km
0151015 LX DIN SIR-GL-S-Round 2X1.5 100 kg/km
0151017 LX DIN PVC-PVC - Oval 2X1.5 70 kg/km
0151019 LX DIN SIR-GL - Oval 2X1.5 50 kg/km
0151022 LX DIN SIR-SIR - Round 2X1.5 80 kg/km
0151023 LX DIN SIR-SIR-S-Round 2X1.5 120 kg/km
0151030 LX DIN PVC-PVC - Round 2X0.5 45 kg/km
0151035 LX DIN PVC-PVC - Round 2X0.75 56 kg/km
0151040 LX DIN SIR-SIR-S-Oval 2X0.5 51 kg/km
0151050 LX DIN SIR-SIR-S-Oval 2X0.75 58 kg/km
0151051 LX DIN PVC-PVC - Round 2X0.22 22 kg/km
0151052 LX DIN PVC-PVC-C-PVC - Round 2X0.22 48 kg/km
0152001 KCA DIN PVC-Round 2X1.5 40 kg/km
0152003 KCA DIN SIR-Round 2X1.5 40 kg/km
0152005 KCA DIN GL-GL - Oval 2X1.5 50 kg/km
0152006 KCA DIN GL-GL-S-Oval 2X1.5 80 kg/km
0152007 KCA DIN SIR-SIR-S-Oval 2X1.5 90 kg/km
0152010 KCA DIN PVC-PVC - Round 2X1.5 79 kg/km
0152011 KCA DIN PVC-PVC-S-Round 2X1.5 140 kg/km
0152015 KCA DIN SIR-GL-S-Round 2X1.5 100 kg/km
0152017 KCA DIN PVC-PVC - Oval 2X1.5 70 kg/km
0152019 KCA DIN SIR-GL - Oval 2X1.5 50 kg/km
0152022 KCA DIN SIR-SIR - Round 2X1.5 80 kg/km
0152023 KCA DIN SIR-SIR-S-Round 2X1.5 120 kg/km
0152030 KCA DIN SIR-SIR-S-Oval 2X0.5 51 kg/km
0152035 KCA DIN SIR-SIR-S-Oval 2X0.75 58 kg/km
0152040 KCA DIN PVC-PVC - Round 2X0.5 45 kg/km
0152045 KCA DIN PVC-PVC - Round 2X0.75 56 kg/km
0152051 KCA DIN PVC-PVC - Round 2X0.22 22 kg/km
0152052 KCA DIN PVC-PVC-C-PVC - Round 2X0.22 31 kg/km
0153005 SCB DIN GL-GL - Oval 2X1.5 50 kg/km
0153006 SCB DIN GL-GL-S-Oval 2X1.5 80 kg/km
0153007 SCB DIN SIR-SIR-S-Oval 2X1.5 90 kg/km
0153010 SCB DIN PVC-PVC - Round 2X1.5 79 kg/km
0153015 SCB DIN SIR-GL-S-Round 2X1.5 100 kg/km
0153019 SCB DIN SIR-GL - Oval 2X1.5 50 kg/km
0153022 SCB DIN SIR-SIR - Round 2X1.5 80 kg/km
0153023 SCB DIN SIR-SIR-S-Round 2X1.5 120 kg/km
0153051 SCB DIN PVC-PVC - Round 2X0.22 22 kg/km
0153052 SCB DIN PVC-PVC-C-PVC - Round 2X0.22 31 kg/km
0154010 KX DIN PVC-PVC - Round 2X1.5 79 kg/km
0154011 LX DIN PVC-ST-PVC - Round 2X1.5 85 kg/km
0154012 KCA DIN PVC-ST-PVC - Round 2X1.5 85 kg/km
0154013 KX DIN PVC-ST-PVC - Round 2X1.5 85 kg/km
0154014 SCB DIN PVC-ST-PVC - Round 2X1.5 85 kg/km
0157513 KCA DIN PVC-PVC-S-PVC - Round 2X1.5 160 kg/km
0157514 LX DIN PVC-PVC-S-PVC - Round 2X1.5 160 kg/km
0157515 SCB DIN PVC-PVC-S-PVC - Round 2X1.5 160 kg/km
0161001 JX IEC PVC-Round 2X1.5 40 kg/km
0161003 JX IEC SIR-Round 2X1.5 40 kg/km
0161005 JX IEC GL-GL - Oval 2X1.5 50 kg/km
0161006 JX IEC GL-GL-S-Oval 2X1.5 80 kg/km
0161007 JX IEC SIR-SIR-S-Oval 2X1.5 90 kg/km
0161010 JX IEC PVC-PVC - Round 2X1.5 100 kg/km
0161011 JX IEC PVC-PVC-S-Round 2X1.5 140 kg/km
0161015 JX IEC SIR-GL-S-Round 2X1.5 100 kg/km
0161017 JX IEC PVC-PVC - Oval 2X1.5 70 kg/km
0161019 JX IEC SIR-GL - Oval 2X1.5 50 kg/km
0161022 JX IEC SIR-SIR - Round 2X1.5 80 kg/km
0161023 JX IEC SIR-SIR-S-Round 2X1.5 120 kg/km
0161030 JX IEC PVC-PVC - Round 2X0.5 45 kg/km
0161035 JX IEC PVC-PVC - Round 2X0.75 56 kg/km
0161040 JX IEC SIR-SIR-S-Oval 2X0.5 51 kg/km
0161050 JX IEC SIR-SIR-S-Oval 2X0.75 58 kg/km
0161051 JX IEC PVC-PVC - Round 2X0.22 22 kg/km
0161052 JX IEC PVC-PVC-C-PVC - Round 2X0.22 31 kg/km
0162001 KCA IEC PVC-Round 2X1.5 40 kg/km
0162003 KCA IEC SIR-Round 2X1.5 40 kg/km
0162005 KCA IEC GL-GL - Oval 2X1.5 50 kg/km
0162006 KCA IEC GL-GL-S-Oval 2X1.5 80 kg/km
0162007 KCA IEC SIR-SIR-S-Oval 2X1.5 90 kg/km
0162010 KCA IEC PVC-PVC - Round 2X1.5 79 kg/km
0162011 KCA IEC PVC-PVC-S-Round 2X1.5 140 kg/km
0162015 KCA IEC SIR-GL-S-Round 2X1.5 100 kg/km
0162017 KCA IEC PVC-PVC - Oval 2X1.5 70 kg/km
0162019 KCA IEC SIR-GL - Oval 2X1.5 50 kg/km
0162022 KCA IEC SIR-SIR - Round 2X1.5 80 kg/km
0162023 KCA IEC SIR-SIR-S-Round 2X1.5 120 kg/km
0162030 KCA IEC SIR-SIR-S-Oval 2X0.5 51 kg/km
0162035 KCA IEC SIR-SIR-S-Oval 2X0.75 58 kg/km
0162040 KCA IEC PVC-PVC - Round 2X0.5 45 kg/km
0162045 KCA IEC PVC-PVC - Round 2X0.75 56 kg/km
0162051 KCA IEC PVC-PVC - Round 2X0.22 22 kg/km
0162052 KCA IEC PVC-PVC-C-PVC - Round 2X0.22 31 kg/km
0163005 SCB IEC GL-GL - Oval 2X1.5 50 kg/km
0163006 SCB IEC GL-GL-S-Oval 2X1.5 80 kg/km
0163007 SCB IEC SIR-SIR-S-Oval 2X1.5 90 kg/km
0163010 SCB IEC PVC-PVC - Round 2X1.5 79 kg/km
0163015 SCB IEC SIR-GL-S-Round 2X1.5 82 kg/km
0163022 SCB IEC SIR-SIR - Round 2X1.5 76 kg/km
0163023 SCB IEC SIR-SIR-S-Round 2X1.5 120 kg/km
0163051 SCB IEC PVC-PVC - Round 2X0.22 22 kg/km
0163052 SCB IEC PVC-PVC-C-PVC - Round 2X0.22 31 kg/km
0164010 KX IEC PVC-PVC - Round 2X1.5 79 kg/km
0164011 JX IEC PVC-ST-PVC - Round 2X1.5 85 kg/km
0164012 KCA IEC PVC-ST-PVC - Round 2X1.5 85 kg/km
0164013 KX IEC PVC-ST-PVC - Round 2X1.5 85 kg/km
0164014 SCB IEC PVC-ST-PVC - Round 2X1.5 85 kg/km
0167513 KCA IEC PVC-PVC-S-PVC - Round 2X1.5 160 kg/km
0167514 JX IEC PVC-PVC-S-PVC - Round 2X1.5 160 kg/km
0167515 SCB IEC PVC-PVC-S-PVC - Round 2X1.5 160 kg/km
1161004 J IEC GL-GL-S-Round 2X0.22 82 kg/km
1161005 K IEC GL-GL-S-Round 2X0.22 82 kg/km
1161007 K IEC FEP-C-FEP - Round 2X0.22 22 kg/km
1161008 K IEC FEP-FEP - Oval 2X0.5 10 kg/km
1161009 K IEC GL-GL - Oval 2X0.5 7 kg/km
1161011 KCA IEC FEP-SIR - Round 2X0.22 22 kg/km
1161012 KCA IEC SIR-GL-S-Oval 2X1.5 82 kg/km
1161014 J IEC GL-GL-S-Round 2X0.35 82 kg/km