NYCY 4x4 RE/4 0,6/1kV
Power cables; 4x4 RE/4; U0/U: 0,6 / 1 kV; Bare Copper; PVC; VDE certified; Fixed Installation

Please click on “Request for Quote” for price information and stock availability
In stock
SKU
15503223
In stock and estimated delivery in 3 weeks
For Back Ordering of Out of Stock items in India & Globally, Tentative Lead Time is 4 - 6 Weeks. The actual delivery date will be confirmed within 3 to 5 days after placing an order
NYCY 4x4 RE/4 0,6/1kV Power cables -  Primary Image
NYCY 4x4 RE/4 0,6/1kV Power cables -  Primary Image
uv-resistant.
uv-resistant.
flame-retardant
flame-retardant
CE marked
CE marked
VDE certified
VDE certified

Benefits

  • Suitable for direct underground installation thanks to tough insulation and sheath material (PVC). The robust materials protect against harmful environmental influences and chemicals.
  • A common core wrapping made of a filling compound ensures additional strength of the cable.
  • An additional outer copper conductor is positioned concentrically around the core sheath and can be used as protective cable conduits (PE), protective and neutral conductors (PEN) or screening.
  • A cross-conductive copper tape coil around the concentric conductor reduces inductance.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
  • VDE-certified cable with ◁VDE▷ testing mark for proven reliability and quality.

Applications

  • Can be used universally for connecting the power supply in buildings and industrial facilities.
  • Suitable for energy distribution in power and converter stations.
  • For fixed installation in water, air, earth and concrete. In the ground, the minimum installation depth without additional, suitable protection is 0.6 m, and at least 0.8 m under roads.
  • Can be used in dry, damp or wet environments.
  • Suitable for medium mechanical stress.
  • Suitable for outdoor use, subject to the temperature range.
Show less
Show all

Technical Attributes

General Information

Product type

Power cables

Weight

485 kg/km

Copper index

200.000 kg/km

Copper index (lb)

1343.945 lb/10,000 ft

Electrical Characteristics

Nominal voltage

U0/U: 0,6 / 1 kV AC rms according to IEC

Test voltage

4 kV

Current rating according to

VDE 0276-603

Product Design

N-German standard cables

NYCY

Conductor number/size

4X4 RE/4

Conductor cross-section (mm2)

4 mm²

Conductor material

Bare Copper

Conductor design

IEC 60228 class 1: solid conductor

Conductor shape

Round

Conductor short form

4x4 RE/4

Including protective conductor

Yes

Concentric conductor

Yes

type of concentric conductor

Helical bare copper wires with cross-conducting coil

Number of cores

4

Filling compound over the core assembly

Yes

Shielded

No

Min. outer diameter

16 mm

Nominal outer diameter

16 mm

Max. outer diameter

20 mm

Shape of cable

Round

Core insulation base material

Polyvinylchloride

Core insulation base material, shortname

PVC

Base material outer sheath

Polyvinylchloride

Base material outer sheath, shortname

PVC

Cable insulation colour

black

Core identification

Colours

Core colour code

VDE 0293-308

Product Characteristics

Application area

Fixed Installation

Suitable for underground installation

direct
in cable trench
in protective cable conduit

For torsional load

No

Minimum bending radius, fixed installation

12 x outer diameter

Minimum bending radius in mm, fixed installation

240.0 mm

Temperature, fixed installation

-40 °C to 70 °C

Min. installation temperature

-5 °C

Installation temperature max.

50 °C

Flame-retardant

Yes

Flame retardance according to

IEC 60332-1-2

UV-resistant

Yes

UV-resistant according to

EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use)

Halogenfree

No

Oil-resistant

No

PWIS-free

Yes

LABS-free according to

VDMA 24364-B2-L

Certifications and Standards

CE marked

Yes

UKCA marked

No

EAC certified

Yes

EAC certification number

ЕАЭС RU С-DE.АЮ64.В.00091/19, ЕАЭС RU С-DE.АЮ64.В.00110/20

VDE certified

Yes

Product standard VDE

VDE 0276-603

HAR-certified

No

CPR fire class

Eca

Flame retardance tested according to UN/ECE-R118

No

Show less
Show all

Documentation

  • Notes

    • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
    • Trade product, not a LAPP product.
    • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.

Product Family List

All articles from NYCY

Article number Conductor short form Min. outer diameter Max. outer diameter Copper index Weight
1550299 2x2.5 RE/2.5 17 mm 21 mm 80.000 kg/km 241 kg/km
15503003 2x1.5 RE/1.5 52.000 kg/km 245 kg/km
15503103 3x1.5 RE/1.5 66.000 kg/km 280 kg/km
15503113 3x2.5 RE/2.5 104.000 kg/km 310 kg/km
15503123 3x4 RE/4 14 mm 18 mm 161.000 kg/km 384 kg/km
1550313 3x6 RE/6 16 mm 20 mm 240.000 kg/km 484 kg/km
15503203 4x1.5 RE/1.5 81.000 kg/km 280 kg/km
15503213 4x2.5 RE/2.5 128.000 kg/km 360 kg/km
1550322 7x4 RE/4 16 mm 20 mm 315.000 kg/km 621 kg/km
15503223 4x4 RE/4 16 mm 20 mm 200.000 kg/km 485 kg/km
15503233 4x6 RE/6 17 mm 21 mm 297.000 kg/km 616 kg/km
1550330 7x1.5 RE/2.5 17 mm 21 mm 133.000 kg/km 450 kg/km
1550332 12x1.5 RE/2.5 17 mm 21 mm 205.000 kg/km 580 kg/km
1550337 24x1.5 RE/6 17 mm 21 mm 413.000 kg/km 1100 kg/km
1550350 7x2.5 RE/2.5 17 mm 21 mm 200.000 kg/km 530 kg/km
1550355 16x2.5 RE/6 17 mm 21 mm 451.000 kg/km 950 kg/km
Show less