Power and control cable; 4G1.5; U0/U: 450/750 V; PUR; Core identification: Colours; Flexible
Benefits
- The combination of the very robust cable design and the wide temperature range in which it can be used provides a wide range of applications..
- Made according to harmonised European type H05BQ-F or H07BQ-F (depending on the conductor cross-section), with the ◁HAR▷ testing mark for proven reliability and quality.
- ◁HAR▷-style cables are widely accepted and can be used in Europe.
- Durable, resistant product thanks to the outer sheath PU material that is resistant to abrasions, notches and cuts.
- Outer sheath with orange signal colour for rapid visual perception and prevention of accidents and damage.
- Suitable for voltage classes 300/500 V or 450/750 V depending on the conductor cross-section.
Applications
- Power cable for construction machinery and mobile electrical handheld devices.
- Typical fields of application include building sites, camping, event technology, agriculture, etc.
- For fixed installation and occasional flexing without tensile strain.
- Can be used in dry, damp and, especially, harsh and oily environments.
- The PUR outer sheath withstands high mechanical loads.
- The PUR outer sheath is resistant to mineral oil-based lubricants and highly resistant to chemicals.
- Suitable for outdoor use.
- Flexible use at temperatures down to -40°C.
Technical Attributes
General Information
Brand
ÖLFLEX®
Product type
Power and control cable
Weight
137 kg/km
Copper index
58.000 kg/km
copper index (lb)
389.700 lb/10,000 ft
Electrical Characteristics
Nominal voltage
U0/U: 450/750 V AC rms according to IEC
Test voltage
3 kV
Current rating according to
VDE 0298-4
Max. conductor resistance at 20°C
13.3 Ω/km
Product Design
Harmonised design
H07BQ-F
Cable dimension
4G1.5
Conductor cross-section (mm2)
1.5 mm²
Conductor material
Bare Copper
Conductor design
IEC 60228 class 5: fine-wire
Including protective conductor
Yes
Number of cores
4
Stranding type
Layered Stranding
Shielded
No
Min. outer diameter
9 mm
Max. outer diameter
11.6 mm
Shape of cable
Round
Core insulation base material
Ethylene propylene diene rubber
Core insulation base material, shortname
EPDM
Base material of outer sheath
Polyurethane
Base material of outer sheath, shortname
PUR
Cable insulation colour
orange
Cable insulation RAL colour
RAL 2003
Core identification
Colours
Core colour code
VDE 0293-308
Product Characteristics
Application area
FlexibleFixed Installation
Minimum bending radius, fixed installation
4 x outer diameter
Minimum bending radius in mm, stationary
46.4 mm
Minimum bending radius, occasionally moved
12.5 x outer diameter
Minimum bending radius in mm, occasionally flexing
145.0 mm
temperature, fixed installation
-50 °C to 90 °C
Temperature, occasionally moved
-40 °C to 90 °C
Storage temperature min.
-25 °C
Storage temperature max.
55 °C
Flame-retardant
No
UV-resistant
Yes
UV-resistant according to
EN ISO 4892-2, method A (colour change permitted)
weather resistant
Yes
Chemical resistant
Yes
hydrolysis resistant
Yes
Halogenfree
Yes
Oil-resistant
Yes
Oil resistance according to
EN 50363-10-2
PWIS-free
Yes
PWIS-free according to
VDMA 24364-B2-L
Certifications and Standards
CE marked
Yes
EAC certified
Yes
EAC certification number
ЕАЭС N RU Д-DE.АЮ64.В.00130/20
UL recognised
No
UL listed
No
cUR recognized
No
cUL listed
No
CSA certified
No
VDE certified
No
HAR-certified
Yes
Product standard DIN / EN
EN 50525-2-21
Flame retardance tested according to UN/ECE-R118
No
Ecolab certified
No
Documentation
-
Downloads
Further Links
-
Notes
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
- Trade product, not a LAPP product.
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
Product Family List
All articles from H05BQ-F / H07BQ-F
Article number | Number of cores | Including protective conductor | Conductor cross-section (mm2) | Nominal voltage | Copper index | Weight | ||
---|---|---|---|---|---|---|---|---|
0013600 | 2 | No | 0.75 mm² | U0/U: 300/500 V AC rms according to IEC | 14.400 kg/km | 50 kg/km | ||
0013601 | 3 | Yes | 0.75 mm² | U0/U: 300/500 V AC rms according to IEC | 21.600 kg/km | 80 kg/km | ||
00136023 | 4 | Yes | 0.75 mm² | U0/U: 300/500 V AC rms according to IEC | 28.800 kg/km | 78 kg/km | ||
00136033 | 5 | Yes | 0.75 mm² | U0/U: 300/500 V AC rms according to IEC | 36.000 kg/km | 98 kg/km | ||
0013610 | 2 | No | 1 mm² | U0/U: 300/500 V AC rms according to IEC | 19.200 kg/km | 60 kg/km | ||
0013611 | 3 | Yes | 1 mm² | U0/U: 300/500 V AC rms according to IEC | 29.000 kg/km | 74 kg/km | ||
00136123 | 4 | Yes | 1 mm² | U0/U: 300/500 V AC rms according to IEC | 38.400 kg/km | 92 kg/km | ||
00136133 | 5 | Yes | 1 mm² | U0/U: 300/500 V AC rms according to IEC | 48.000 kg/km | 114 kg/km | ||
0013620 | 2 | No | 1.5 mm² | U0/U: 450/750 V AC rms according to IEC | 29.000 kg/km | 87 kg/km | ||
0013621 | 3 | Yes | 1.5 mm² | U0/U: 450/750 V AC rms according to IEC | 43.000 kg/km | 108 kg/km | ||
00136223 | 4 | Yes | 1.5 mm² | U0/U: 450/750 V AC rms according to IEC | 58.000 kg/km | 137 kg/km | ||
00136233 | 5 | Yes | 1.5 mm² | U0/U: 450/750 V AC rms according to IEC | 72.000 kg/km | 165 kg/km | ||
0013630 | 2 | No | 2.5 mm² | U0/U: 450/750 V AC rms according to IEC | 48.000 kg/km | 90 kg/km | ||
0013631 | 3 | Yes | 2.5 mm² | U0/U: 450/750 V AC rms according to IEC | 72.000 kg/km | 161 kg/km | ||
00136323 | 4 | Yes | 2.5 mm² | U0/U: 450/750 V AC rms according to IEC | 96.000 kg/km | 206 kg/km | ||
00136333 | 5 | Yes | 2.5 mm² | U0/U: 450/750 V AC rms according to IEC | 120.000 kg/km | 254 kg/km |