NYCWY 3x50 SM/50 0,6/1kV
Power cables; 3x50 SM; U0/U: 0,6 / 1 kV; Bare Copper; PVC; Concentric conductor; VDE certified; Fixed Installation

₹8,403.96
BACK ORDER
Article No.
15505163
(₹8,403.96/M)
Inclusive of tax
Free Delivery within 3 weeks from payment receipt
Unit Per Unit Per MOQ
100 ₹6,521.47 ₹652,147.00
300₹5,706.29₹1,711,887.00
500₹5,054.14₹2,527,070.00
Minimum order quantity 100 meters. You can order multiples of 100 meters
X


For Back Ordering of Out of Stock items in India & Globally, Tentative Lead Time is 4 - 6 Weeks. The actual delivery date will be confirmed within 3 to 5 days after placing an order
NYCWY 3x50 SM/50 0,6/1kV Power cables -  Primary Image
NYCWY 3x50 SM/50 0,6/1kV Power cables -  Primary Image
uv-resistant.
uv-resistant.
flame-retardant
flame-retardant
CE marked
CE marked
VDE certified
VDE certified

Benefits

  • Suitable for direct underground installation thanks to tough insulation and sheath material (PVC). The robust materials protect against harmful environmental influences and chemicals.
  • A common core wrapping made of a filling compound ensures additional strength of the cable.
  • An additional outer copper conductor is positioned concentrically around the core sheath and can be used as protective cable conduits (PE), protective and neutral conductors (PEN) or screening. The wave-shaped arrangement simplifies connection.
  • A cross-conductive copper tape coil around the concentric conductor reduces inductance.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
  • VDE-certified cable with ◁VDE▷ testing mark for proven reliability and quality.

Applications

  • Can be used universally for connecting the power supply in buildings and industrial facilities.
  • Suitable for energy distribution in power and converter stations.
  • For fixed installation in water, air, earth and concrete. In the ground, the minimum installation depth without additional, suitable protection is 0.6 m, and at least 0.8 m under roads.
  • Can be used in dry, damp or wet environments.
  • Suitable for medium mechanical stress.
  • Suitable for outdoor use, subject to the temperature range.
Show less
Show all

Technical Attributes

General Information

Product type

Power cables

Weight

2368 kg/km

Copper index

2000.000 kg/km

Copper index (lb)

13439.450 lb/10,000 ft

Electrical Characteristics

Nominal voltage

U0/U: 0,6 / 1 kV AC rms according to IEC

Test voltage

4 kV

Current rating according to

VDE 0276-603

Product Design

N-German standard cables

NYCWY

Conductor number/size

3X50 SM/50

Conductor cross-section (mm2)

50 mm²

Conductor material

Bare Copper

Conductor design

IEC 60228 class 2: multi-wire

Conductor shape

Sector-shaped

Conductor short form

3x50 SM

Including protective conductor

Yes

Concentric conductor

Yes

type of concentric conductor

Wave-like bare copper wires with cross-conducting coil

Number of cores

3

Shielded

No

Min. outer diameter

26 mm

Max. outer diameter

33 mm

Shape of cable

Round

Core insulation base material

Polyvinylchloride

Core insulation base material, shortname

PVC

Base material outer sheath

Polyvinylchloride

Base material outer sheath, shortname

PVC

Cable insulation colour

black

Core identification

Colours

Core colour code

VDE 0293-308

Product Characteristics

Application area

Fixed Installation

Suitable for underground installation

direct
in cable trench
in protective cable conduit

For torsional load

No

Minimum bending radius, fixed installation

12 x outer diameter

Minimum bending radius in mm, fixed installation

396.0 mm

Temperature, fixed installation

-40 °C to 70 °C

Min. installation temperature

-5 °C

Installation temperature max.

50 °C

Flame-retardant

Yes

Flame retardance according to

IEC 60332-1-2

UV-resistant

Yes

UV-resistant according to

EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use)

Halogenfree

No

Oil-resistant

No

PWIS-free

Yes

LABS-free according to

VDMA 24364-B2-L

Certifications and Standards

CE marked

Yes

UKCA marked

No

EAC certified

Yes

EAC certification number

ЕАЭС RU С-DE.АЮ64.В.00091/19, ЕАЭС RU С-DE.АЮ64.В.00110/20

VDE certified

Yes

Product standard VDE

VDE 0276-603

HAR-certified

No

CPR fire class

Eca

Flame retardance tested according to UN/ECE-R118

No

Show less
Show all

Documentation

Product Family List

All articles from NYCWY

Article number Conductor short form Min. outer diameter Max. outer diameter Copper index Weight
15503293 4x240 RE 47 mm 54 mm 10546.000 kg/km 12409 kg/km
15505003 2x10 RE 312.000 kg/km 610 kg/km
15505133 3x70 RE 47 mm 54 mm 2410.000 kg/km 2940 kg/km
15505143 3x95 SM/50 35 mm 42 mm 3296.000 kg/km 4256 kg/km
15505153 3x120 SM 38 mm 45 mm 4236.000 kg/km 5314 kg/km
15505163 3x50 SM 26 mm 33 mm 2000.000 kg/km 2368 kg/km
15505173 3x185 SM 47 mm 54 mm 6383.000 kg/km 8054 kg/km
15505263 3x10 RE 18 mm 22 mm 408.000 kg/km 775 kg/km
15505273 3x16 RE 20 mm 24 mm 643.000 kg/km 1066 kg/km
15505283 3x25 RM 25 mm 31 mm 1003.000 kg/km 1584 kg/km
15505303 3x35 SM 25 mm 31 mm 1402.000 kg/km 1710 kg/km
15505323 3x95 SM 35 mm 42 mm 3791.000 kg/km 4600 kg/km
15505353 3x150 SM 42 mm 49 mm 5100.000 kg/km 6344 kg/km
15505403 4x10 RE 19 mm 23 mm 504.000 kg/km 897 kg/km
15505413 4x16 RE 21 mm 25 mm 796.000 kg/km 1250 kg/km
15505423 4x25 RM 25 mm 32 mm 1142.000 kg/km 1822 kg/km
15505433 4x35 SM 26 mm 33 mm 1526.000 kg/km 2140 kg/km
15505443 4x50 SM 29 mm 36 mm 2203.000 kg/km 3031 kg/km
15505453 4x70 SM 34 mm 41 mm 3082.000 kg/km 4056 kg/km
15505463 4x95 SM 40 mm 47 mm 4208.000 kg/km 5364 kg/km
15505473 4x120 SM 43 mm 50 mm 5388.000 kg/km 6748 kg/km
15505483 4x150 SM 47 mm 54 mm 6540.000 kg/km 8159 kg/km
15505493 4x185 RE 47 mm 54 mm 8159.000 kg/km 9850 kg/km
Show less
Show all

Why Choose Lapp ?

Why Choose LAPP as a Preferred Partner?