NHXMH-J 3x2,5 RE
Installation cable; U0/U: 300/500 V; HFFR; Core identification: Colours; VDE certified; Fixed Installation
Benefits
- Halogen free and highly flame retardant materials reduce the risk of flame propagation, high smoke density and toxic flue gases in the event of a fire.
- VDE-certified cable with ◁VDE▷ testing mark for proven reliability and quality.
- Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection on the LAPP website.
Applications
- For the power supply connection to buildings and industrial plants, in compliance with special fire protection requirements.
- For installation on, in or under plaster, in brickwork and in stationary concrete. Not suitable for direct embedding in vibrated or compressed concrete.
- Can be used in dry, damp or wet environments.
- Suitable for light to medium mechanical stress.
- Suitable for outdoor use, subject to the temperature range and only if protected against direct sunlight.
Technical Attributes
General Information
Product type
Installation cable
Weight
149 kg/km
Copper index
72.000 kg/km
copper index (lb)
483.800 lb/10,000 ft
Electrical Characteristics
Nominal voltage
U0/U: 300/500 V AC rms according to IEC
Test voltage
2 kV
Current rating according to
VDE 0298-4
Max. conductor resistance at 20°C
7.41 Ω/km
Product Design
N-German standard cables
NHXMH-J
Conductor count/size
3x2,5
Conductor cross-section (mm2)
2.5 mm²
Conductor material
Bare Copper
Conductor design
IEC 60228 class 1: solid conductor
Including protective conductor
Yes
Number of cores
3
Filling compound over the core assembly
Yes
Shielded
No
Min. outer diameter
8.7 mm
Max. outer diameter
10.6 mm
Shape of cable
Round
Core insulation base material
Cross-linked polyethylene
Core insulation base material, shortname
XLPE
Base material of outer sheath
Halogen-free compound
Base material of outer sheath, shortname
HFFR
Cable insulation colour
grey
Core identification
Colours
Core colour code
VDE 0293-308
Product Characteristics
Application area
Fixed Installation
Minimum bending radius, fixed installation
4 x outer diameter
Minimum bending radius in mm, stationary
42.4 mm
temperature, fixed installation
-40 °C to 70 °C
Installation temperature min.
5 °C
Installation temperature max.
70 °C
Flame-retardant
Yes
Flame retardance according to
IEC 60332-3-24
UV-resistant
No
weather resistant
No
Ozone resistant
No
Halogenfree
Yes
Zero halogen according to
EN 50267-2-2
Oil-resistant
No
PWIS-free
No
Certifications and Standards
CE marked
Yes
EAC certified
Yes
EAC certification number
ЕАЭС N RU Д-DE.АЮ64.В.00130/20, ЕАЭС N RU Д-DE.АЮ64.В.00142/20
VDE certified
Yes
Product standard VDE
VDE 0250-214
Flame retardance tested according to UN/ECE-R118
No
Documentation
-
Downloads
Further Links
-
Notes
- Photographs and graphics are not to scale and do not represent detailed images of the respective products.
- Trade product, not a LAPP product.
- Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
Product Family List
All articles from NHXMH
Article number | Number of cores | Including protective conductor | Conductor cross-section (mm2) | Min. outer diameter | Copper index | Weight | |
---|---|---|---|---|---|---|---|
16020003 | 3 | Yes | 1.5 mm² | 8 mm | 43.000 kg/km | 114 kg/km | |
16020013 | 4 | Yes | 1.5 mm² | 8.5 mm | 58.000 kg/km | 145 kg/km | |
16020023 | 5 | Yes | 1.5 mm² | 9.1 mm | 72.000 kg/km | 166 kg/km | |
1602003 | 7 | Yes | 1.5 mm² | 9.9 mm | 101.000 kg/km | 198 kg/km | |
16020103 | 3 | Yes | 2.5 mm² | 8.7 mm | 72.000 kg/km | 149 kg/km | |
16020123 | 5 | Yes | 2.5 mm² | 10.2 mm | 120.000 kg/km | 220 kg/km |