ÖLFLEX® CLASSIC 100 SY 4G2,5
Power and control cable; 4G2.5; U0/U: 450 / 750 V; PVC; Core identification: Colours; Flexible

Register for Price
SKU
00160893
($7.19/Ft) Excluding Tax




No standard cuts available
No residual cuts available
ÖLFLEX® CLASSIC 100 SY 4G2,5 Power and control cable -  Primary Image
ÖLFLEX® CLASSIC 100 SY 4G2,5 Power and control cable -  Primary Image
chemical resistance
chemical resistance
flame-retardant
flame-retardant
UKCA marked
UKCA marked
CE marked
CE marked

Benefits

  • High electrical safety thanks to 4000 V test voltage.
  • Additional robustness thanks to the extruded inner sheath.
  • Classified fire behaviour according to EU Directive 305/2011 (BauPVO/CPR) with article number selection at www.lappkabel.de/cpr.

Applications

  • For universal use for wiring machine-internal and cross-plant control circuits.
  • For fixed installation and occasional flexing without tensile strain.
  • Can be used in dry, damp or wet interiors.
  • Suitable for medium mechanical stress.
  • The PVC outer sheath is resistant to acids and alkalis.
Show less
Show all

Technical Attributes

General Information

Product type

Power and control cable

weight

0.339 kg

Copper index (lb)

645.000 lb/10,000 ft

copper index

96.000 kg/km

Electrical Characteristics

Test voltage

4 kV

Product Design

Cable dimension

4G2.5

Nominal conductor cross-section (mm2)

2.5 mm²

conductor design

IEC 60228 class 5: fine-wire

Including protective conductor

Yes

Number of cores

4

Type of stranding

Layered Stranding

Shielded

No

With armour

Yes

Armouring type

Galvanised Steel Wire Braiding

Nominal outer diameter

13.9 mm

Shape of cable

Round

Core insulation base material

Polyvinyl chloride

Core insulation basic material, short form

PVC

Base material inner sheath

Polyvinyl chloride

Base material inner sheath shortname

PVC

colour inner sheath

grey

Base material outer sheath

Polyvinyl chloride

Basic material of outer sheath, short form

PVC

Outer sheath colour

transparent

Core identification

Colours

core colour code

VDE 0293-1
VDE 0293-308 (LAPP appendix T9)

Product Characteristics

Application type

Flexible
Fixed Installation

For torsional load

No

Minimum bending radius, fixed installation

6 x outer diameter

Minimum bending radius in mm, fixed installation

83.4 mm

Minimum bending radius, occasionally moved

20 x outer diameter

Minimum bending radius in mm, occasionally moved

278.0 mm

Flame-retardant

Yes

Flame retardance according to

IEC 60332-1-2

UV-resistant

No

Chemical resistant

Yes

Halogen-free

No

Oil resistant

No

PWIS-free

Yes

Certifications and Standards

CE marking

Yes

UKCA marked

Yes

EAC certified

Yes

EAC certification number

ЕАЭС N RU Д-DE.АЮ64.В.00130/20

VDE certified

No

CPR fire behaviour classified

Eca

Flame retardance tested according to UN/ECE-R118

No

Show less
Show all

Product Family List

All articles from ÖLFLEX® CLASSIC 100 SY

Article number Number of cores Including protective conductor Nominal conductor cross-section (mm2) Nominal voltage Nominal outer diameter copper index weight
0016023 3 Yes 0.75 mm² U0/U: 300 / 500 V AC rms after IEC 8.5 mm 21.600 kg/km 0.108 kg
0016027 7 Yes 0.75 mm² U0/U: 300 / 500 V AC rms after IEC 10.3 mm 50.000 kg/km 0.172 kg
0016042 2 No 1 mm² U0/U: 300 / 500 V AC rms after IEC 8.5 mm 19.200 kg/km 0.137 kg
0016043 3 Yes 1 mm² U0/U: 300 / 500 V AC rms after IEC 8.8 mm 29.000 kg/km 0.154 kg
00160443 4 Yes 1 mm² U0/U: 300 / 500 V AC rms after IEC 9.5 mm 38.400 kg/km 0.180 kg
00160453 5 Yes 1 mm² U0/U: 300 / 500 V AC rms after IEC 10.1 mm 48.000 kg/km 0.202 kg
* 0016047 7 Yes 1 mm² U0/U: 300 / 500 V AC rms after IEC 11 mm 67.000 kg/km 0.242 kg
0016065 3 Yes 1.5 mm² U0/U: 300 / 500 V AC rms after IEC 9.7 mm 43.000 kg/km 0.191 kg
00160663 4 Yes 1.5 mm² U0/U: 300 / 500 V AC rms after IEC 10.2 mm 58.000 kg/km 0.217 kg
00160673 5 Yes 1.5 mm² U0/U: 300 / 500 V AC rms after IEC 11.1 mm 72.000 kg/km 0.268 kg
0016075 18 Yes 1.5 mm² U0/U: 300 / 500 V AC rms after IEC 17.6 mm 259.000 kg/km 0.652 kg
0016077 25 Yes 1.5 mm² U0/U: 300 / 500 V AC rms after IEC 20.3 mm 360.000 kg/km 0.913 kg
0016088 3 Yes 2.5 mm² U0/U: 450 / 750 V AC rms after IEC 12.6 mm 72.000 kg/km 0.278 kg
00160893 4 Yes 2.5 mm² U0/U: 450 / 750 V AC rms after IEC 13.9 mm 96.000 kg/km 0.339 kg
00160903 5 Yes 2.5 mm² U0/U: 450 / 750 V AC rms after IEC 15.2 mm 120.000 kg/km 0.397 kg
0016092 7 Yes 2.5 mm² U0/U: 450 / 750 V AC rms after IEC 16.3 mm 168.000 kg/km 0.470 kg
0016101 2 No 4 mm² U0/U: 450 / 750 V AC rms after IEC 13.6 mm 76.800 kg/km 0.329 kg
00161023 4 Yes 4 mm² U0/U: 450 / 750 V AC rms after IEC 15.7 mm 154.000 kg/km 0.457 kg
00161033 5 Yes 4 mm² U0/U: 450 / 750 V AC rms after IEC 17.1 mm 192.000 kg/km 0.545 kg
0016106 3 Yes 6 mm² U0/U: 450 / 750 V AC rms after IEC 15.8 mm 173.000 kg/km 0.426 kg
00161073 4 Yes 6 mm² U0/U: 450 / 750 V AC rms after IEC 17.2 mm 230.000 kg/km 0.687 kg
00161083 5 Yes 6 mm² U0/U: 450 / 750 V AC rms after IEC 18.8 mm 288.000 kg/km 0.798 kg
00161103 4 Yes 10 mm² U0/U: 450 / 750 V AC rms after IEC 21.3 mm 384.000 kg/km 1.009 kg
00161113 5 Yes 10 mm² U0/U: 450 / 750 V AC rms after IEC 23.3 mm 480.000 kg/km 1.197 kg
00161133 4 Yes 16 mm² U0/U: 450 / 750 V AC rms after IEC 24.1 mm 614.000 kg/km 1.384 kg
* 00161143 5 Yes 16 mm² U0/U: 450 / 750 V AC rms after IEC 26.8 mm 768.000 kg/km 1.740 kg
00161163 4 Yes 25 mm² U0/U: 450 / 750 V AC rms after IEC 29.4 mm 960.000 kg/km 2.021 kg
00161173 5 Yes 25 mm² U0/U: 450 / 750 V AC rms after IEC 32.6 mm 1200.000 kg/km 2.464 kg
00161183 4 Yes 35 mm² U0/U: 450 / 750 V AC rms after IEC 32.4 mm 1344.000 kg/km 2.570 kg
* 00161193 5 Yes 35 mm² U0/U: 450 / 750 V AC rms after IEC 36 mm 1680.000 kg/km 3.185 kg
Show less
Show all
ACCESSORIES

Why Choose LAPP?

LAPP manufactures the highest quality cable, connectors, glands and industrial communication solutions to enhance factory automation and future-ready industrial manufacturing production systems and equipment. LAPP's state of the art manufacturing plant headquartered in Florham Park, N.J. includes an inhouse UL Client Data Program and UL certified laboratory to ensure the highest quality.