ETHERLINE® TRAY ER PN Y FC 2x2x22
Ethernet cable; Fixed Installation; ETHERNET/IP, PROFINET; PROFINET® application: Type A; Cat.5e; SF/UTP; PVC; green

₹464.09
BACK ORDER
Article No.
2170879
(₹464.09/M)
Inclusive of tax
Free Delivery within 3 weeks from payment receipt
Unit Per Unit Per MOQ
100 ₹371.27 ₹37,127.00
300₹324.86₹97,458.00
500₹287.74₹143,870.00
Minimum order quantity 100 meters. You can order multiples of 100 meters
X


For Back Ordering of Out of Stock items in India & Globally, Tentative Lead Time is 4 - 6 Weeks. The actual delivery date will be confirmed within 3 to 5 days after placing an order
ETHERLINE® TRAY ER PN Y FC 2x2x22 Ethernet cable -  Primary Image
ETHERLINE® TRAY ER PN Y FC 2x2x22 Ethernet cable -  Primary Image ETHERLINE® TRAY ER PN Y FC 2x2x22 Ethernet cable -   Secondary Image ETHERLINE® TRAY ER PN Y FC 2x2x22
uv-resistant.
uv-resistant.
flame-retardant
flame-retardant
icon sturgeon signal
icon sturgeon signal
UKCA marked
UKCA marked
CE marked
CE marked
ETHERNET/IP
ETHERNET/IP
PROFINET
PROFINET
UR recognised US, cUR recognised US
UR recognised US, cUR recognised US
cUL listed US, UL listed US
cUL listed US, UL listed US

Benefits

  • Fast information exchange through Ethernet technology. 
  • Cat. 5 performance up to 100 Mbit/s.
  • High resistance to electromagnetic interference thanks to star quad stranding as well as double screening made of aluminium-laminated foil and high degree of copper screening braiding (SF/UTP).
  • "FC" variants with Fast Connect cable design for easier assembly.
  • UL certification according to technical data enables the product to be used on the North American market.

Applications

  • For fixed installation in the PROFINET network (type A), due to solid conductor design.
  • Also suitable for EtherCAT and EtherNet/IP applications.
  • Suitable for medium mechanical stress.
  • Can be used in dry and damp environments.
  • The PVC outer sheath is resistant to acids and alkalis and has limited oil resistance.
  • Variant "YY" is suitable for outdoor use, subject to the temperature range.
  • "TRAY ER PN Y FC" variant for open installation in cable trays without protective cable conduit.
Show less
Show all

Technical Attributes

General Information

Brand

ETHERLINE®

Product type

Ethernet cable

Weight

70 kg/km

Copper index

30.400 kg/km

Copper index (lb)

204.300 lb/10,000 ft

valid Fieldbus or Ethernet System

PROFINET

Electrical Characteristics

Nominal voltage

48 V AC rms according to IEC

Rated voltage core to core

600 V AC rms according to UL AWM
50 V AC rms according to IEC

Maximum operating voltage (not for power transmission)

125 V

test voltage conductor/conductor

2 kV

Test voltage core/screening

2 kV

DC loop resistance at 20°C

115 Ω/km

Min. insulation resistance

500 MΩ*km

Nominal characteristic impedance

100 Ω

Possible data transmission rates

100 Mbit/s

Signal propagation speed (nom.)

0.67 c

Product Design

Conductor number/size

2x2x22/1AWG

Cable dimension

2X2X22 AWG

Nominal cross section conductor (AWG)

22 AWG

Number of wires

1

Including protective conductor

No

Number of cores

4

Number of pairs

2

Stranding type

Star Quad

Shielded

Yes

Type of overall screen

Aluminium-laminated plastic foil
Tin-plated copper braiding

Abbreviation shielding

SF/UTP

optical degree of coverage overall screen

85 %

With armouring

No

With rodent protection

No

Min. diameter of core

1.4 mm

Nominal diameter of core

1.5 mm

Max. diameter of core

1.6 mm

Min. outer diameter

6.2 mm

Nominal outer diameter

6.5 mm

Max. outer diameter

6.8 mm

Shape of cable

Round

Core insulation base material

Polyethylene

Core insulation base material, shortname

PE

Base material outer sheath, shortname

PVC

Cable insulation colour

green

Colour outer sheath RAL code

RAL 6018

Core identification

Colours

Product Characteristics

Application area

Fixed Installation

PROFINET® application

Type A

Windable

No

Minimum bending radius, fixed installation

10 x outer diameter

Minimum bending radius in mm, fixed installation

68.0 mm

Temperature, fixed installation

-40 °C to 80 °C

Min. installation temperature

-20 °C

Installation temperature max.

60 °C

Flame-retardant

Yes

Flame retardance according to

CSA FT4

UV-resistant

Yes

UV-resistant according to

UL sunlight resistant

Halogenfree

No

Oil-resistant

No

PWIS-free

Yes

LABS-free according to

VDMA 24364-B2-L

Ethernet cable category

Cat.5e

Fast Connect (FC) cable

Yes

Certifications and Standards

CE marked

Yes

UKCA marked

Yes

EAC certified

Yes

EAC certification number

ЕАЭС N RU Д-DE.АЮ64.В.00130/20

UL recognised

Yes

UL AWM certification

20201 according to UL 758 (e-file number: E63634)

UL listed

Yes

UL certification

UL PLTC-ER according to UL 13

cUR recognized

Yes

cUL listed

Yes

cUL certification

cUL CMG (75°C) according to CSA C22.2 No. 214 (e-file number: E236660)

CSA certified

No

VDE certified

No

Show less
Show all

Documentation

Product Family List

All articles from ETHERLINE® PN Cat.5

Article number Conductor number/size Temperature, fixed installation Flame retardance according to Nominal outer diameter Copper index Weight
2170879 2x2x22/1AWG -40 °C to 80 °C CSA FT4 6.5 mm 30.400 kg/km 70 kg/km
2170891 2x2x22/1AWG -40 °C to 70 °C IEC 60332-1-2 6.3 mm 30.400 kg/km 56 kg/km
2170893 2x2x22/1AWG -40 °C to 80 °C IEC 60332-1-2 6.5 mm 30.400 kg/km 70 kg/km
2170933 2x2x22/1AWG -25 °C to 80 °C CSA FT4 7.7 mm 30.400 kg/km 60 kg/km
Show less