KE1L Fe/CuNi LX 2x1,5 DIN
Thermoelectric cable; LX; DIN; PVC-round; 2X1.5

₹417.13
BACK ORDER
Article No.
0151001
(₹417.13/M)
Inclusive of tax
Free Delivery within 3 weeks from payment receipt
Unit Per Unit Per MOQ
1000 ₹235.70 ₹235,700.00
10₹314.26₹3,142.60
100₹274.98₹27,498.00
500+₹235.70₹117,850.00
Minimum order quantity 1000 meters. You can order multiples of 1000 meters
X


For Back Ordering of Out of Stock items in India & Globally, Tentative Lead Time is 4 - 6 Weeks. The actual delivery date will be confirmed within 3 to 5 days after placing an order
KE1L Fe/CuNi LX 2x1,5 DIN Thermoelectric cable -  Primary Image
KE1L Fe/CuNi LX 2x1,5 DIN Thermoelectric cable -  Primary Image

Benefits

  • Space-saving and flexible
  • For more detailed information, see appendix T8 and data sheets

Applications

  • The thermocouple is used to measure temperature as a part of monitoring the manufacturing process, thus the sheath material should be selected with reference to the maximum ambient temperature at its junction.
  • Conductor materials (alloys): Fe/CuNi (LX, JX)Conductor alloys are identical to thermocouple alloys
  • NiCr/Ni (K, KX, KCA)K and KX version - conductor alloys are identical to thermocouple alloysKCA version: compensating alloys (for KCA: Fe/CuNi), not identical to thermocouple alloys
  • PtRh/Pt (RCB, SCB)Compensating alloys (for RCB, SCB: Cu/CuNi) are not identical to thermocouple alloys
  • Allows temperature measurement even in places where non-contact temperature measurement is not possible or reasonable
Show less
Show all

Technical Attributes

General Information

Product type

Thermoelectric cable

Weight

40 kg/km

Product Design

Thermoelectric and compensating cable type

LX

Cable dimension

2X1.5

Conductor cross-section (mm2)

1.5 mm²

Conductor design

48 x 0.20 mm

Including protective conductor

No

Number of cores

2

Shielded

No

With armouring

No

Nominal outer diameter

5.4 mm

Shape of cable

Round

Extension and compensating cables design

PVC-rund

Core insulation base material

Polyvinylchloride

Core insulation base material, shortname

PVC

Core identification

Colours

Core colour code

IEC 60584-3

Thermoelectric and compensating cable colour code

DIN

Product Characteristics

Application area

Flexible
Fixed Installation

Minimum bending radius, fixed installation

12 x outer diameter

Minimum bending radius in mm, fixed installation

64.8 mm

Minimum bending radius, occasionally moved

12 x outer diameter

Minimum bending radius in mm, occasionally flexing

64.8 mm

Temperature, fixed installation

-40 °C to 80 °C

Temperature, occasionally moved

-5 °C to 80 °C

Flame-retardant

No

UV-resistant

No

Chemical resistant

No

Halogenfree

No

Oil-resistant

No

PWIS-free

Yes

LABS-free according to

VDMA 24364-B2-L

Certifications and Standards

CE marked

No

UKCA marked

No

EAC certified

Yes

EAC certification number

ЕАЭС N RU Д-DE.АЮ64.В.00130/20

Flame retardance tested according to UN/ECE-R118

No

Show less
Show all

Product Family List

All articles from Extension- and compensating cables, paired

Article number Thermoelectric and compensating cable type Thermoelectric and compensating cable colour code Extension and compensating cables design Cable dimension Weight
0151001 LX DIN PVC-rund 2X1.5 40 kg/km
0151003 LX DIN SIR-rund 2X1.5 40 kg/km
0151005 LX DIN GL-GL - oval 2X1.5 50 kg/km
0151006 LX DIN GL-GL-S-oval 2X1.5 80 kg/km
0151007 LX DIN SIR-SIR-S-oval 2X1.5 90 kg/km
0151010 LX DIN PVC-PVC - rund 2X1.5 79 kg/km
0151011 LX DIN PVC-PVC-S-rund 2X1.5 140 kg/km
0151015 LX DIN SIR-GL-S-rund 2X1.5 100 kg/km
0151017 LX DIN PVC-PVC - oval 2X1.5 70 kg/km
0151019 LX DIN SIR-GL - oval 2X1.5 50 kg/km
0151022 LX DIN SIR-SIR - rund 2X1.5 80 kg/km
0151023 LX DIN SIR-SIR-S-rund 2X1.5 120 kg/km
0151030 LX DIN PVC-PVC - rund 2X0.5 45 kg/km
0151035 LX DIN PVC-PVC - rund 2X0.75 56 kg/km
0151040 LX DIN SIR-SIR-S-oval 2X0.5 51 kg/km
0151050 LX DIN SIR-SIR-S-oval 2X0.75 58 kg/km
0151051 LX DIN PVC-PVC - rund 2X0.22 22 kg/km
0151052 LX DIN PVC-PVC-C-PVC - rund 2X0.22 48 kg/km
0152001 KCA DIN PVC-rund 2X1.5 40 kg/km
0152003 KCA DIN SIR-rund 2X1.5 40 kg/km
0152005 KCA DIN GL-GL - oval 2X1.5 50 kg/km
0152006 KCA DIN GL-GL-S-oval 2X1.5 80 kg/km
0152007 KCA DIN SIR-SIR-S-oval 2X1.5 90 kg/km
0152010 KCA DIN PVC-PVC - rund 2X1.5 79 kg/km
0152011 KCA DIN PVC-PVC-S-rund 2X1.5 140 kg/km
0152015 KCA DIN SIR-GL-S-rund 2X1.5 100 kg/km
0152017 KCA DIN PVC-PVC - oval 2X1.5 70 kg/km
0152019 KCA DIN SIR-GL - oval 2X1.5 50 kg/km
0152022 KCA DIN SIR-SIR - rund 2X1.5 80 kg/km
0152023 KCA DIN SIR-SIR-S-rund 2X1.5 120 kg/km
0152030 KCA DIN SIR-SIR-S-oval 2X0.5 51 kg/km
0152035 KCA DIN SIR-SIR-S-oval 2X0.75 58 kg/km
0152040 KCA DIN PVC-PVC - rund 2X0.5 45 kg/km
0152045 KCA DIN PVC-PVC - rund 2X0.75 56 kg/km
0152051 KCA DIN PVC-PVC - rund 2X0.22 22 kg/km
0152052 KCA DIN PVC-PVC-C-PVC - rund 2X0.22 31 kg/km
0153005 SCB DIN GL-GL - oval 2X1.5 50 kg/km
0153006 SCB DIN GL-GL-S-oval 2X1.5 80 kg/km
0153007 SCB DIN SIR-SIR-S-oval 2X1.5 90 kg/km
0153010 SCB DIN PVC-PVC - rund 2X1.5 79 kg/km
0153015 SCB DIN SIR-GL-S-rund 2X1.5 100 kg/km
0153019 SCB DIN SIR-GL - oval 2X1.5 50 kg/km
0153022 SCB DIN SIR-SIR - rund 2X1.5 80 kg/km
0153023 SCB DIN SIR-SIR-S-rund 2X1.5 120 kg/km
0153051 SCB DIN PVC-PVC - rund 2X0.22 22 kg/km
0153052 SCB DIN PVC-PVC-C-PVC - rund 2X0.22 31 kg/km
0154010 KX DIN PVC-PVC - rund 2X1.5 79 kg/km
0154011 LX DIN PVC-ST-PVC - rund 2X1.5 85 kg/km
0154012 KCA DIN PVC-ST-PVC - rund 2X1.5 85 kg/km
0154013 KX DIN PVC-ST-PVC - rund 2X1.5 85 kg/km
0154014 SCB DIN PVC-ST-PVC - rund 2X1.5 85 kg/km
0157513 KCA DIN PVC-PVC-S-PVC - rund 2X1.5 160 kg/km
0157514 LX DIN PVC-PVC-S-PVC - rund 2X1.5 160 kg/km
0157515 SCB DIN PVC-PVC-S-PVC - rund 2X1.5 160 kg/km
0161001 JX IEC PVC-rund 2X1.5 40 kg/km
0161003 JX IEC SIR-rund 2X1.5 40 kg/km
0161005 JX IEC GL-GL - oval 2X1.5 50 kg/km
0161006 JX IEC GL-GL-S-oval 2X1.5 80 kg/km
0161007 JX IEC SIR-SIR-S-oval 2X1.5 90 kg/km
0161010 JX IEC PVC-PVC - rund 2X1.5 100 kg/km
0161011 JX IEC PVC-PVC-S-rund 2X1.5 140 kg/km
0161015 JX IEC SIR-GL-S-rund 2X1.5 100 kg/km
0161017 JX IEC PVC-PVC - oval 2X1.5 70 kg/km
0161019 JX IEC SIR-GL - oval 2X1.5 50 kg/km
0161022 JX IEC SIR-SIR - rund 2X1.5 80 kg/km
0161023 JX IEC SIR-SIR-S-rund 2X1.5 120 kg/km
0161030 JX IEC PVC-PVC - rund 2X0.5 45 kg/km
0161035 JX IEC PVC-PVC - rund 2X0.75 56 kg/km
0161040 JX IEC SIR-SIR-S-oval 2X0.5 51 kg/km
0161050 JX IEC SIR-SIR-S-oval 2X0.75 58 kg/km
0161051 JX IEC PVC-PVC - rund 2X0.22 22 kg/km
0161052 JX IEC PVC-PVC-C-PVC - rund 2X0.22 31 kg/km
0162001 KCA IEC PVC-rund 2X1.5 40 kg/km
0162003 KCA IEC SIR-rund 2X1.5 40 kg/km
0162005 KCA IEC GL-GL - oval 2X1.5 50 kg/km
0162006 KCA IEC GL-GL-S-oval 2X1.5 80 kg/km
0162007 KCA IEC SIR-SIR-S-oval 2X1.5 90 kg/km
0162010 KCA IEC PVC-PVC - rund 2X1.5 79 kg/km
0162011 KCA IEC PVC-PVC-S-rund 2X1.5 140 kg/km
0162015 KCA IEC SIR-GL-S-rund 2X1.5 100 kg/km
0162017 KCA IEC PVC-PVC - oval 2X1.5 70 kg/km
0162019 KCA IEC SIR-GL - oval 2X1.5 50 kg/km
0162022 KCA IEC SIR-SIR - rund 2X1.5 80 kg/km
0162023 KCA IEC SIR-SIR-S-rund 2X1.5 120 kg/km
0162030 KCA IEC SIR-SIR-S-oval 2X0.5 51 kg/km
0162035 KCA IEC SIR-SIR-S-oval 2X0.75 58 kg/km
0162040 KCA IEC PVC-PVC - rund 2X0.5 45 kg/km
0162045 KCA IEC PVC-PVC - rund 2X0.75 56 kg/km
0162051 KCA IEC PVC-PVC - rund 2X0.22 22 kg/km
0162052 KCA IEC PVC-PVC-C-PVC - rund 2X0.22 31 kg/km
0163005 SCB IEC GL-GL - oval 2X1.5 50 kg/km
0163006 SCB IEC GL-GL-S-oval 2X1.5 80 kg/km
0163007 SCB IEC SIR-SIR-S-oval 2X1.5 90 kg/km
0163010 SCB IEC PVC-PVC - rund 2X1.5 79 kg/km
0163015 SCB IEC SIR-GL-S-rund 2X1.5 82 kg/km
0163022 SCB IEC SIR-SIR - rund 2X1.5 76 kg/km
0163023 SCB IEC SIR-SIR-S-rund 2X1.5 120 kg/km
0163051 SCB IEC PVC-PVC - rund 2X0.22 22 kg/km
0163052 SCB IEC PVC-PVC-C-PVC - rund 2X0.22 31 kg/km
0164010 KX IEC PVC-PVC - rund 2X1.5 79 kg/km
0164011 JX IEC PVC-ST-PVC - rund 2X1.5 85 kg/km
0164012 KCA IEC PVC-ST-PVC - rund 2X1.5 85 kg/km
0164013 KX IEC PVC-ST-PVC - rund 2X1.5 85 kg/km
0164014 SCB IEC PVC-ST-PVC - rund 2X1.5 85 kg/km
0167513 KCA IEC PVC-PVC-S-PVC - rund 2X1.5 160 kg/km
0167514 JX IEC PVC-PVC-S-PVC - rund 2X1.5 160 kg/km
0167515 SCB IEC PVC-PVC-S-PVC - rund 2X1.5 160 kg/km
1161007 KX IEC FEP-C-FEP - rund 2X0.22 22 kg/km
1161008 KX IEC FEP-FEP - oval 2X0.5 10 kg/km
1161009 KX IEC GL-GL - oval 2X0.5 7 kg/km
1161011 KCA IEC FEP-SIR - rund 2X0.22 22 kg/km
1161012 KCA IEC SIR-GL-S-oval 2X1.5 82 kg/km
Show less
Show all

Why Choose Lapp ?

Why Choose LAPP as a Preferred Partner?